  apm - 40 series ac/dc power module 4 0 w, industrial & medical safety e - mail:sales@minmax.com.tw tel:886 - 6 - 2923150 201 5 / 0 5 / 22 rev:2 page 1 of 5 features ? fully encapsulated plastic case fo r pcb, chassis and din - rail mounting versio n ? universal input 85~264vac, 47~440h z ? protection class ii as per iec/en 6053 6 ? i/o isolation 4000vac with reinforced insulatio n ? operating temp. range - 40 to +80 ? overload/voltage/temp. and short circuit protectio n ? emi emission meets en55011/22 class b & fcc level b ? emc immunity meets en61000 - 4 - 2,3,4,5,6,8,1 1 ? ul/ cul/iec/en 60950 - 1 and ul508 safety approva l ? medical safety meets 2xmopp per 3 rd edition of iec/en 60601 - 1 & ansi/aami es60601 - 1 ? ce marking with emc and lv d product overview the new minmax a p m - 4 0 series is a range of fully encapsulated ac/dc power modules. these high performance products feature an extended operating temperature range of - 40c to +80c. universal input voltage 85 - 264vac and ul/iec/en safety approvals including medical safety and u l508 listing qualify these power supplies modules for applications in products with worldwide markets.emi - filter meets en55022, class b and fcc,part15, class b. the a p m - 4 0 series power modules provide an economical solution for many space critical applicat ions in commercial, medical and industrial electronic equipment. model selection guide model number output voltage output current input current max. c apacitive load efficiency (typ.) 1 1 5vac, 60hz 230vac, 50hz max. @max. load @max. load , 11 5vac vdc ma ma( t yp.) f % apm - 4 0s05 5 8 000 716 4 29 8000 81 apm - 40 s 12 12 333 0 6 89 41 4 3900 8 4 apm - 40 s1 5 15 2 66 0 6 80 4 08 3900 8 5 apm - 40 s 24 24 166 0 687 41 3 680 84 apm - 40d12 12 166 0 687 41 3 1500# 84 apm - 40d15 15 133 0 6 80 4 08 1 0 00# 8 5 # for each output input specifications parameter model min. typ. max. unit ac voltage input range all models 85 --- 264 v a c input frequency range 47 --- 440 hz dc voltage input range 120 --- 370 vdc no - load power consumption --- --- 0.3 w in rush current (cold start at 25 ) 1 1 5vac --- --- 30 a 230vac --- --- 60 a
apm - 40 series ac/dc power module 4 0 w, industrial & medical safety e - mail:sales@minmax.com.tw tel:886 - 6 - 2923150 201 5 / 0 5 / 22 rev:2 page 2 of 5 output specifications parameter conditions min. typ. max. unit output voltage accuracy --- 2 .0 --- % vom. line regulation vin=min. to max. @full load --- 0 .5 --- % load regulation io=0% to 100% single output model --- 1.0 --- % dual output models --- 2.0 --- % min imum load no minimum load requirement ripple & noise (3) 0 - 20 mhz bandwidth 5v output models --- 1.5 1.8 %v pp of vo other output models --- 1.0 1.3 %v pp of vo over voltage protection zener diode clamp --- 120 --- % of vo temperature coefficient --- 0.02 --- %/ overshoot --- --- 5 % current limitation 85vac, hiccup mode, auto - recovery 105 --- --- % inom. (long term overload condition may cause damage) short circuit protection hiccup mode, indefinite (a utomatic r ecovery) general specifications parameter conditions min. typ. max. unit i/o isolation voltage reinforced insulation, rated for 60 seconds 4000 --- --- v a c rms leakage current --- 80 --- a i/o isolation resistance 500 vdc 10 00 --- --- m switching frequency --- 1 30 --- khz hold - up time 1 1 5vac, 60hz --- 25 --- ms 230vac, 50hz --- 8 0 --- ms mtbf (calculated) mil - hdbk - 217f@25 , ground benign 200,000 hours protection class ii according iec/en 60536 safety approvals iec/en 60950 - 1 cb report, ul/ c ul 60950 - 1, csa - c22.2 no.60950 - 1, ul508 listed certificate iec/en 60601 - 1 3 rd edition cb report, ansi/aami es60601 - 1 2xmopp, can/csa - c22.2 no.60601 - 1 certificate e mc specifications parameter standards & level performance emi conduction en55011, en55022, en61000 - 6 - 4, en61000 - 6 - 3, fcc part 15 class b radiation ems en60601 - 1 - 2, en55024, en61000 - 6 - 2, en61000 - 6 - 1 esd en61000 - 4 - 2 a ir 8 k v , contact 4k v a radiated immunity en61000 - 4 - 3 10v/m a fast transient en61000 - 4 - 4 2 k v a surge en61000 - 4 - 5 1k v a conducted immunity en61000 - 4 - 6 10v rms a pfmf en61000 - 4 - 8 30a/ m a dips en61000 - 4 - 11 30% 10ms a interruptions en61000 - 4 - 11 >95% 5000ms b environmental specifications parameter conditions min. max. temperature range (operational) ambient - 40 + 80 power derating above +60 1.5w / storage temperature range - 40 + 95 over temperature protection shutdown at 90 (automatic recovery at approx. 67 ) humidity (non condensing) --- 95 % rel. h cooling natural c onvection lead temperature (1.5mm from case for 10sec.) --- 260
apm - 40 series ac/dc power module 4 0 w, industrial & medical safety e - mail:sales@minmax.com.tw tel:886 - 6 - 2923150 201 5 / 0 5 / 22 rev:2 page 3 of 5 notes 1 this product is not designed for use in critical life support systems, equipment used in hazardous environment, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 2 specifications typical at ta=+25 , resistive load, 1 1 5vac, 60hz input voltage, after warm - up time rated output current unless otherwise noted. 3 ripple & noise measured with a 0. 1 f /50v mlcc and a 1 f /50v aluminum electrolytic . 4 safety approvals cover frequency 47 - 63 hz. 5 we recommend to protect the converter by a slow blow fuse in the input supply line. 6 other input and output voltage may be available, please contact factory . 7 that natural convection is about 20lfm but is not equal to still air (0 lfm). 8 specifications are subject to change without notice . package specifications pcb mounting mechanical dimensions pin connections pin single output dual output 1 ac (n) ac (n) 2 ac (l ) ac ( l ) 3 +vout +vout 4 no pin no pin 5 - vout common 6 no pin no pin 7 nc - vout nc: no connection ? all dimensions in mm (inches) ? tolerance: 0. 5 (0.0 2 ) ? pin diameter ? 1.0 0.1 (0.0 4 0.004) physical characteristics case size : 88.9 x 63. 5 x 30 . 0 mm ( 3.50 x 2. 50 x 1.18 i nches) case material : plastic resin ( flammability to ul 94v - 0 rated ) pin material : copper alloy with gold plate over nickel subplate weight : 310g 31 . 6 [ 1 . 24 ] 55 . 88 [ 2 . 20 ] 63 . 5 [ 2 . 50 ] 8 1 . 3 [ 3 . 2 0 ] 8 8 . 9 [ 3 . 5 0 ] 15 . 24 12 . 7 7 6 5 4 3 1 2 5 . 0 30 . 0 6 . 0 1 . 0 [ 0 . 60 ] [ 0 . 50 ] 12 . 7 [ 0 . 50 ] 15 . 24 [ 0 . 60 ] [ 0 . 24 ] [ 1 . 18 ] 0 . 7 [ 0 . 03 ] [ 0 . 0 4 ] [ 0 . 2 0 ] mounting m 4 . 0 thread bottom view 15 . 9 [ 0 . 63 ] 5 3 . 3 [ 2 . 1 0 ]
apm - 40 series ac/dc power module 4 0 w, industrial & medical safety e - mail:sales@minmax.com.tw tel:886 - 6 - 2923150 201 5 / 0 5 / 22 rev:2 page 4 of 5 package specifications chassis mounting (order code suffix c) mechanical dimensions connections pin single output dual output 1 ac (n) ac (n) 2 ac (l) ac (l) 3 +vout +vout 4 nc nc 5 - vout common 6 nc nc 7 nc - vout nc: no connection ? all dimensions in mm (inches) ? tolerance: 0. 5 (0.0 2 ) physical characteristics case size : 112.0 x 63.8 x 34.1 mm (4.41 x 2.51 x 1.34 i nches) case material : plastic resin ( flammability to ul 94v - 0 rated ) weight : 320g package specifications with din rail mounting bracket mechanical dimensions physical characteristics case size : 112.0x63.8x34.1 mm (4.41 x2.51x1.34 i nches) case material : plastic resin ( flammability to ul 94v - 0 rated ) weight : 374g 92.0 [3.62] 100.0 [3.94] 112.0 [4.41] 6 3 . 8 [ 2 . 5 1 ] 5 0 . 0 [ 1 . 9 7 ] 4 x 3.5 top view 1 2 3 4 5 6 7 10.0 [0.39] power "good" indicator indication led dc- on 5 . 0 [ 0 . 2 0 ] 1 6 . 8 [ 0 . 6 6 ] 3 4 . 1 [ 1 . 3 4 ] 92.0 [3.62] 100.0 [3.94] 112.0 [4.41] 6 3 . 8 [ 2 . 5 1 ] 5 0 . 0 [ 1 . 9 7 ] 4 x 3.5 top view 1 2 3 4 5 6 7 10.0 [0.39] power "good" indicator indication led dc- on 1 6 . 8 [ 0 . 6 6 ] 3 4 . 1 [ 1 . 3 4 ] 1 1 . 0 [ 0 . 4 3 ] 3 . 0 [ 0 . 1 2 ] 5 . 0 [ 0 . 2 0 ]
a pm - 40 series ac/dc power module 4 0 w, industrial & medical safety minmax technology co., ltd. 18, sin sin road, an - ping industrial district, tainan 702, taiwan tel: 886 - 6 - 2923150 fax: 886 - 6 - 2923149 e - mail: sales@minmax.com.tw 201 5 / 0 5 / 22 rev:2 page 5 of 5 din - rail mounting bracket ( order code for kit : ac - din - 0 2 ) order code table pcb mounting chassis mounting with din rail mounting by two order code apm - 40s05 apm - 40s05 c apm - 40s05 c ac - din - 02 apm - 40s12 apm - 40s12 c apm - 40s12 c ac - din - 02 apm - 40s15 apm - 40s15 c apm - 40s15 c ac - din - 02 apm - 40s24 apm - 40s24 c apm - 40s24 c ac - din - 02 apm - 40d12 apm - 40d12 c apm - 40d12 c ac - din - 02 apm - 40d15 apm - 40d15 c apm - 40d15 c ac - din - 02 apm - 40s05 apm - 40s05 c apm - 40s05 c ac - din - 02


▲Up To Search▲   

 
Price & Availability of APM-40

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X